Plinth
# ENGR 101/102 Cornerstone Design: Semester Project Brief ## Project Title Early Detection and Alert System for Wildfire Risk on Rural and Wildland Urban Interface Properties ## Course Context This project is issued to a team of five first year engineering students as the capstone deliverable for a two semester introductory design sequence. Teams are expected to move through the full engineering design process: problem definition, research, concept generation, concept selection, detailed design, prototyping, testing, and a final design review, over the course of approximately fifteen weeks. No prior hardware or programming experience is assumed. The course provides baseline instruction in CAD, basic circuits, and introductory programming, but the team is expected to research anything beyond that baseline on their own. ## Problem Statement Colorado properties located in the wildland urban interface, meaning land where homes and forest or grassland fuel sources sit close together, face a wildfire risk that often goes unnoticed until a fire is already large enough to threaten structures. Utility scale monitoring networks and satellite detection systems exist, but they are built for regional agencies, not individual property owners, and they can take significant time to confirm a small ignition. A property owner with a single acre lot bordering open land currently has no affordable way to get an early, localized warning that conditions on their own property have become dangerous or that a fire has actually started nearby. Your team's task is to design, build, and test a standalone device that a homeowner could mount on their own property to provide earlier localized warning than they would otherwise get, using sensors, a simple decision algorithm, and a clear alert mechanism, all built to a cost point that makes it realistic for an individual homeowner rather than a utility or government agency. ## Background and Motivation Wildfire risk in Colorado has increased in both frequency and severity over the past two decades, and much of the affected housing stock sits directly adjacent to undeveloped land. Two separate but related problems exist for a homeowner in this situation. The first is elevated risk conditions on their own property, meaning a combination of high temperature, low humidity, and dry vegetation that makes ignition more likely. The second is an active nearby ignition, meaning smoke or heat signatures indicating a fire has already started within detection range of the property. Your system should address at least the first problem, and may address the second as a stretch goal, but the team should scope this decision deliberately rather than by default. This is a real, unresolved problem. Teams should not assume the answer is obvious. Part of the semester's work is confirming, through research and outreach if possible, that the problem is real and that your specific approach is a reasonable one, not just an assumption carried from week one. ## Constraints - **Budget.** Total bill of materials cost may not exceed 150 dollars per unit at the prototype stage, excluding tools that are reused across the project. This constraint exists because the target user is an individual homeowner, not an institution. - **Power.** The device must be able to run unattended outdoors for at least 30 days on battery power, solar assisted power, or a combination of both. It may not require a permanent wired connection to grid power, since many candidate mounting locations (fence lines, tree lines, outbuildings) will not have one available. - **Environment.** The enclosure and all exposed components must tolerate outdoor exposure across a Colorado seasonal range, roughly negative 20 to 100 degrees Fahrenheit, along with rain, snow, and direct sun. - **Alerting.** The device must be able to notify a homeowner who is not standing next to it at the moment an alert triggers. A local light or buzzer alone does not satisfy this constraint. Wireless notification of some kind, whether through a home Wi Fi connection, a cellular module, or another method the team justifies, is required. - **Safety.** No component of the design may introduce a fire, electrical, or chemical hazard that would itself create risk on the property it is meant to protect. This is a hard constraint the instructor will check explicitly at the design review. - **Timeline.** All fifteen weekly milestones below are fixed. Slipping a milestone requires a written justification submitted to the instructor within 48 hours of the missed date. ## Deliverables and Weekly Schedule **Week 1 to 2: Problem Definition and Research** Submit a one page problem statement, three sources of background research (existing detection products, wildfire risk data for your target region, and relevant safety codes), and a list of at least five open questions the team still needs to answer. **Week 3: Stakeholder Input** Identify and, if possible, interview at least one person who represents your target user (a homeowner in a wildland urban interface area, a local fire department representative, or a property insurance professional). Submit a summary of what you learned and how it changed or confirmed your problem statement. **Week 4 to 5: Concept Generation and Selection** Generate at least three distinct concepts for how the device could sense risk and communicate an alert. Build a weighted decision matrix scoring each concept against your constraints (cost, power, reliability, ease of installation, false alarm risk). Submit the matrix along with a one paragraph justification for the concept you selected. **Week 6: Preliminary Design Review** Present your selected concept to the instructor and a panel of peer teams. Include a rough sketch or CAD model of the enclosure, a block diagram of the electronics (sensors, microcontroller, power source, communication module), and your current bill of materials with running cost total. **Week 7 to 9: Detailed Design and Build** Finalize your CAD model and have it reviewed before ordering or 3D printing any enclosure parts. Finalize your circuit design and order components. Begin assembly. Submit a build log at the end of week 9 documenting what has been assembled, what has not, and any deviations from the week 6 design. **Week 10 to 11: Firmware and Integration** Write and test the logic that reads sensor data, determines whether an alert condition is met, and triggers the notification path. Submit your code along with a written explanation of your alert threshold logic and why you chose those thresholds. **Week 12: Verification Testing** Test the complete system against a written test plan you develop yourselves. At minimum this must include a controlled test of the alert threshold (for example, using a heat source to confirm the device correctly triggers), a battery life test or projection, and an enclosure exposure check (water resistance at minimum). Submit your test plan and your results, including any tests that failed and what you changed in response. **Week 13: Peer Review** Exchange devices and documentation with another team. Submit a written review of another team's system evaluating it against the same constraints your own team was held to, and receive a review of your own system in return. **Week 14: Final Revisions** Address any issues surfaced in verification testing or peer review. Submit a final change log describing what was modified since week 12 and why. **Week 15: Final Design Review** Present the completed device to the instructor and an outside panel (industry guest reviewers when available). Deliverables at this stage are the physical prototype, a final design report, and a ten minute team presentation with time for questions. ## Team Structure and Roles Each team of four to five students should assign, and may rotate, the following roles across the semester. Roles do not exempt a student from understanding the whole project, they exist to assign accountability for specific deliverables. - **Project lead.** Owns the weekly schedule, coordinates milestone submissions, and is the primary point of contact with the instructor. - **Mechanical lead.** Owns the enclosure design, CAD model, and material selection. - **Electrical lead.** Owns the circuit design, sensor selection, and power system. - **Software lead.** Owns the firmware, alert logic, and communication integration. - **Documentation and test lead.** Owns the build log, test plan, test results, and final design report formatting. ## Final Design Report Requirements The final report should include, at minimum: the original and any revised problem statement, your concept selection matrix and rationale, final bill of materials with per unit cost, CAD drawings or renders of the enclosure, a circuit schematic, your firmware logic explained in plain language, your full test plan and results, a discussion of what you would change with more time or budget, and individual contribution statements from each team member. ## Grading Considerations Grading should weight process as heavily as outcome. A team that rigorously tested a device with a modest but honestly reported failure mode should not be penalized relative to a team that skipped verification and reported an untested success. Evaluators should specifically check for evidence that the team revised their approach based on real feedback (stakeholder input in week 3, peer review in week 13) rather than treating those weeks as formalities. ## Notes for This Being Used as a Plinth Test Case This brief is written at the level of detail and ambiguity a real freshman team would actually receive, including constraints that are not fully specified (for example, the notification method is left for the team to justify rather than prescribed) and milestones that require judgment calls rather than a single correct answer. This is intentional, since the point of using it to test Plinth is to see how the platform handles an open ended, multi week, multi discipline project with real constraints rather than a fully specified build list.
Still to buy: $0.00 sourced · $0.00 estimated · $133.06 source unknown
Saved USD planning prices for parts still to buy. Tax and shipping excluded; this does not include past purchases.
Environmental sensors measuring temperature, humidity, smoke/gas, and IR flame presence to detect elevated wildfire risk or active ignition
DHT22 Temperature & Humidity Sensor with Cable
digikey
SEN0137
Still to buy / Source not recorded
NTC 10kΩ Thermistor (Bead, outdoor temp backup)
digikey
MF52A2103J3470
Still to buy / Source not recorded
Red 5mm LED (Alert Indicator)
digikey
151051RS11000
Still to buy / Source not recorded
MQ-2 Smoke / Combustible Gas Sensor Module (Adafruit #3199 or equivalent)
other
MQ-2-MODULE
Still to buy / Source not recorded
Solar panel, LiPo battery, and charge management circuit providing unattended outdoor power for 30+ days without grid connection
MCP73831 LiPo Charge Controller IC (SOT23-5)
digikey
MCP73831T-2ACI/OT
Still to buy / Source not recorded
L7805CV 5V 1.5A Linear Voltage Regulator TO-220
digikey
L7805CV
Still to buy / Source not recorded
5V 1W Solar Panel (outdoor, for trickle charging)
other
SOLAR-5V-1W
Still to buy / Source not recorded
Lithium Ion 18650 Battery 3.7V 2.2Ah
digikey
1781
Still to buy / Source not recorded
Cellular module that sends SMS or data alerts to the homeowner when risk thresholds are exceeded, satisfying the off-site notification constraint
Adafruit SIM7080G CAT-M/NB-IoT Cellular + GPS Breakout (Adafruit #4867)
other
4867
Still to buy / Source not recorded
Weatherproof enclosure, mounting hardware, and cable glands protecting electronics across Colorado outdoor temperature range and precipitation
IP65 Weatherproof Project Enclosure (ABS, ~150x100x70mm)
other
ENCL-IP65-150X100
Still to buy / Source not recorded
Microcontroller that reads all sensor data, runs the alert threshold logic, and triggers the cellular notification path
Source unknown $133.06
Still-to-buy priced subtotal: $133.06 USD
9-week plan
All long-lead parts ordered + Arduino IDE running on every team laptop
Place orders immediately for all four long-lead items: MQ-2 smoke sensor, 5V 1W solar panel, Adafruit SIM7080G cellular breakout, and IP65 ABS enclosure — these have unknown lead times and must be in-hand before Week 7 build begins. Simultaneously, install the Arduino IDE on every team member's machine, confirm board support for the Arduino Nano Every, and submit the one-page problem statement with three background research sources and your open-questions list.
Stakeholder interview done; 3 concepts sketched; parts delivery tracked
Conduct the required stakeholder interview (WUI homeowner, fire department contact, or insurance professional) and submit the written summary. Begin concept generation in parallel: sketch at least three distinct sensor-plus-alert concepts before next week. Confirm order status on all long-lead items and escalate to a secondary supplier if any show delays beyond two weeks — the SIM7080G is critical-path for all firmware work.
Weighted decision matrix submitted; concept selected with written justification
Score all three concepts against the five constraints (cost, 30-day power, reliability, install ease, false-alarm risk) in a weighted decision matrix. The cellular-plus-solar concept should score highest on the notification and power constraints — document why. Submit the matrix and one-paragraph justification. This locks your architecture so detailed design can start immediately next week without backtracking.
Arduino Nano Every blinking LED; DHT22 temperature & humidity reading to Serial
Now that in-stock parts have arrived, start hands-on microcontroller work. Upload the blink sketch to confirm the Nano Every toolchain is solid, then wire the DHT22 and read live temperature and humidity values to the Serial Monitor. This is the first sensor you'll integrate because it is the lowest-risk component and builds confidence with Arduino libraries before tackling the more complex MQ-2 and cellular module.
Preliminary Design Review delivered; BOM under $150; enclosure CAD drafted
Present the selected concept to the instructor panel with your block diagram (Nano Every → sensors → power system → SIM7080G → SMS alert), a rough CAD sketch of the IP65 enclosure layout, and a live BOM with running cost total. Mechanical lead should have cable gland locations and component mounting strategy drafted in CAD. This review gates any 3D-printed or custom-cut part orders, so sign-off today prevents a week of lost fabrication lead time.
MQ-2 smoke sensor reading to Serial; NTC thermistor voltage divider tested
Integrate the MQ-2 smoke/gas sensor — allow it to heat up for the manufacturer-specified warm-up period before reading, then log analog values to Serial and identify the baseline vs. smoke-present voltage. Wire the NTC 10kΩ thermistor in a voltage divider and convert ADC counts to Celsius. Sequencing these two sensors this week (before the cellular module) keeps firmware complexity low while you build intuition for what "normal" and "alert" readings actually look like on your hardware.
SIM7080G sends first test SMS; cellular AT command flow documented
Wire the SIM7080G to the Nano Every over UART and work through the AT command sequence to register on the CAT-M network and send a test SMS to a team member's phone. This is the highest-risk integration step in the project — cellular modules are finicky about baud rate, SIM card activation, and antenna placement — so dedicate the full week to it and document every AT command exchange. Getting a working SMS path now means firmware week can focus on logic, not debugging connectivity.
Power system assembled; solar trickle charge confirmed; 18650 runtime logged
Assemble the power chain: solar panel → MCP73831 charge controller → 18650 cell → L7805CV 5V regulator → Nano Every and peripherals. Measure actual current draw of the full sensor-plus-cellular stack with a multimeter, calculate expected battery life at that draw, and verify the solar panel provides meaningful trickle charge in direct sun. The L7805CV will dissipate significant heat stepping 3.7V–4.2V down to 5V — check its thermal behavior and add a heatsink if needed. This week must finish before the enclosure goes together.
All sensors + cellular running together; build log submitted
This is the dedicated debugging week. Bring every subsystem together on the breadboard — DHT22, MQ-2, NTC thermistor, LED indicator, SIM7080G, and the power system — and confirm they all operate simultaneously without interference. Use the lab oscilloscope to check for noise on sensor lines when the cellular module transmits (a known GSM/LTE issue). Fix any I/O conflicts, power brownouts, or library clashes before writing alert logic. Document what works, what doesn't, and your remediation plan in the Week 9 build log.
Generated by Plinth's AI agents. Verify before purchasing parts, following the schedule, or making safety-critical decisions.
Generated by Plinth - turn a project idea into a real buildable plan.